RESA FRIGORIFERA
COOLING CAPACITY
RAFFREDDAMENTO
MECHANICAL
MECCANICO
COOLING
I GB
R407C
WMA0551 WMA0661
DP
-
Pa
0 50 100 0 50 100
Pvent - kW 0.70 0.70 0.70 0.70 0.70 0.70
Portata d'aria
Airflow
FA - l/s
-m³/h
1270 1210 1140 1270 1210 1140
4580 4350 4100 4580 4350 4100
Text = 30°C
Text = 35°C
24°C
40%
Text = 40°C
Text = 45°C
Text = 30°C
Text = 35°C
24°C
50%
26°C
45%
28°C
40%
Text = 40°C
Text = 45°C
Text = 30°C
Text = 35°C
Text = 40°C
Text = 45°C
Text = 30°C
Text = 35°C
Text = 40°C
Text = 45°C
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
15.0 14.9 14.6 16.8 16.5 16.4
15.0 14.9 14.6 16.8 16.5 16.0
14.6 14.4 14.2 16.3 16.0 15.8
14.6 14.4 14.2 16.3 16.0 15.8
14.1 13.9 13.8 15.7 15.5 15.3
14.1 13.9 13.8 15.7 15.5 15.3
13.6 13.5 13.3 15.1 14.9 14.7
13.6 13.5 13.3 15.1 14.9 14.7
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
15.4 15.3 15.2 17.5 17.4 17.3
13.9 13.6 13.2 14.8 14.4 14.1
14.9 14.8 14.7 16.9 16.8 16.7
13.7 13.4 13.0 14.6 14.2 13.8
14.3 14.2 14.1 16.2 16.1 16.0
13.5 13.2 12.8 14.3 14.0 13.6
13.8 13.7 13.6 15.5 15.4 15.3
13.3 13.0 12.6 14.1 13.7 13.3
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
15.8 15.7 15.6 18.0 17.9 17.7
15.3 14.9 14.4 16.2 15.8 15.3
15.2 15.1 15.1 17.3 17.2 17.1
15.2 14.7 14.3 16.0 15.6 15.1
14.7 14.6 14.5 16.6 16.5 16.4
14.7 14.6 14.1 15.7 15.3 14.8
14.3 14.1 13.9 15.9 15.8 15.7
14.3 14.1 13.9 15.5 15.1 14.6
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
TOT - kW
SENS - kW
16.3 16.1 15.9 18.4 18.2 18.1
16.3 16.1 15.9 17.8 17.3 16.7
15.9 15.7 15.5 17.6 17.6 17.4
15.9 15.7 15.5 17.6 17.0 16.5
15.4 15.2 15.0 17.1 16.9 16.7
15.4 15.2 15.0 17.1 16.9 16.3
14.9 14.7 14.5 16.5 16.2 16.0
14.9 14.7 14.5 16.5 16.2 16.0
DP Pressione di mandata
Delivery pressure
Pvent Potenza assorbita dai ventilatori
Fan absorbed power
FA Portata d'aria
Air volume
Text Temp. satura dell’aria esterna
Outdoor Temperature
TOT Potenza frigorifera totale
Total cooling capacity
SENS Potenza frigorifera sensibile
Sensible cooling capacity
NOTA: le rese frigorifere di tutte le unità sono al lordo della
NOTE: The cooling capacities of the units are gross of fan motor gains;
potenza erogata dai ventilatori; per ottenere i valori netti
to obtain net values deduct P
vent
from the TOT and SENS capacities
sottrarre P
vent
dalle rese indicate TOT e SENS.
indicated